We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.

DOD, SOC, SOH Explained: Key Parameters of Energy Storage Batteries

Views : 805
Author : XH-Virginia
Update time : 2025-09-04 10:03:15

As renewable adoption accelerates, the Energy Storage Battery has become the foundation of every Energy Storage System. To design or manage such systems effectively, it is essential to understand the technical parameters that define battery performance. At XIHO Energy, we believe three indicators—DOD, SOC, and SOH—are central to unlocking reliable storage solutions.

Battery Capacity (Ah)
Capacity measures how much energy a battery can deliver. For example, a 48V 100Ah cell equals 4.8 kWh. Capacity values are usually divided into rated, theoretical, and actual capacity. In practical use, actual capacity is always influenced by temperature, charge/discharge rate, and cycle conditions.

Nominal Voltage (V)
Nominal voltage defines the standard operating voltage. In packs, cells are connected in series (increasing voltage) or parallel (increasing capacity). A 24S pack of 3.2V cells equals 76.8V nominal voltage, which directly impacts system design.

C-rate (Charge/Discharge Rate)
C-rate determines how fast a battery can charge or discharge. For instance, a 200Ah battery discharged at 100A equals 0.5C, emptying in two hours. This is often reflected in large Energy Storage Systems, where designers use MW/MWh ratings.

Depth of Discharge (DOD)
DOD is the percentage of energy withdrawn in one cycle. Higher DOD increases usable energy but reduces cycle life. For long-term operation, engineers usually recommend partial discharges to balance usability and lifespan.

State of Charge (SOC)
SOC measures remaining energy, ranging from 0% (empty) to 100% (full). SOC helps operators know how much energy is available at any given moment.

State of Health (SOH)
SOH evaluates the current performance compared to the battery’s original condition. When capacity drops below 80%, replacement is recommended. Monitoring SOH ensures system stability and reduces risks.

In short, parameters like DOD, SOC, and SOH are not abstract—they are the language of battery performance. With XIHO Energy, you gain deeper insight into these values and the expertise to apply them in building a stable, future-ready Energy Storage System.

Welcome to contact us:

WhatsApp/Wechat/Mobile: +86 13332949210

Email: info@xihobattery.com

Website: www.xihobattery.com

Related News
Read More >>
EVE Energy Showcases Energy Solutions at 2026 World UAV Expo EVE Energy Showcases Energy Solutions at 2026 World UAV Expo
Jun .05.2026
The 2026 World UAV Expo and International Low-Altitude Economy & Unmanned Systems Exhibition (UASE 2026) recently concluded at the Shenzhen World Exhibition & Convention Center. The event gathered industry leaders, technology developers, and commercial operators from the global drone and advanced air mobility sectors. Among the prominent exhibitors was EVE Energy, which presented a comprehensive portfolio of energy solutions tailored for low-altitude aviation and robotics applications.
240 pcs of CATL 3.2V 104Ah LiFePo4 batteries to Australia 240 pcs of CATL 3.2V 104Ah LiFePo4 batteries to Australia
Jun .04.2026
We have successfully shipped 240 pcs of CATL 3.2V 104Ah LiFePo4 prismatic battery cells to our customer in Australia. All units passed strict internal resistance (≤0.4mΩ) and voltage inspection before dispatch. The batch has completed packaging, passed weighing verification (each cell weighs 1.95kg), and is now awaiting transportation arrangements. These prismatic cells feature a compact size (52.3 * 148.2 * 119mm), support 1C/3C discharge rates, and offer a long cycle life of 4000+ times—ideal for grid energy storage and commercial industrial applications.
Sodium Ion Battery: The Emerging Energy Storage Solution for Global ESS & EV Projects Sodium Ion Battery: The Emerging Energy Storage Solution for Global ESS & EV Projects
Jun .03.2026
Sodium Ion Battery has rapidly emerged as a reliable low-cost energy storage alternative to lithium-based batteries for global ESS integrators and C&I storage project buyers. Built with abundant sodium-sourced raw materials, our industrial prismatic Sodium Ion Battery delivers outstanding low-temperature performance from -40℃ to 60℃ alongside over 6000 charge-discharge cycles, effectively easing raw material price volatility risks troubling lithium supply chains.
Adapting the i-MiEV Battery Pack for 93Ah NMC Cell Integration Adapting the i-MiEV Battery Pack for 93Ah NMC Cell Integration
Jun .01.2026
Upgrade your Mitsubishi i-MiEV’s performance and range with this high-capacity CATL 93Ah NMC battery pack replacement, designed to directly upgrade the original 50Ah LEV50 cells.This 88S1P configuration delivers 316.8V, 93Ah and 30kWh of total capacity, boosting your i-MiEV’s driving range to up to 300 km on a full charge — a significant improvement over the factory setup.The 93Ah NMC cells feature slightly different physical dimensions and terminal layouts compared to the original LEV50 batteries.